home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

TOR-toroidal (20VA-5kVA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIB for medical devices (0.3:2kVA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)
TTI-K NON LINEAR LOADS (15-300kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz
UP TO 9A

frequency converters 60-50Hz
FROM 20A TO 65A

GMM frequency converters 60-50Hz
FROM 3kVA TO 15kVA

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

SINGLE PHASE CONTROL TRANSFORMERS ET range

 
POWER INPUT OUTPUT FREQUENCY STANDARDS
FROM 50VA TO 3000VA 220-240V

12-24V

55-110V

240V

50/60 Hz EN 61558-2-2
CEI 96-9
380-415-440V CEI 96-1
BS 171
 Open type
 Protection IP00
 Isolation class E (Amb.temp. max 45°C)
 Separate copper windings cl. F-H
 Resin impregnated and tropicalised
 Color coded labels for easies identification of the sec. voltages
 (purple=12-24V; white=24-48V; yellow=55-110V; blue=110-220V)
 Copper earth screen between windings
 Double fixing centres



single phase control transformers

power part no. losses sh.circuit dimensions mm. DWG weight box
VA W volt. % A B C D E F G kg. code
50 ET0050xxxyyy 8 16.2 77 69 88 62 45 50 4 A 1.1 MB01
100 ET0100xxxyyy 14 9.2 87 80 96 71 56 63 5 A 1.9 MB01
200 ET0200xxxyyy 18 5.2 100 102 105 82 57 78 5 A 2.8 MB02
300 ET0300xxxyyy 30 4.6 125 102 135 99 70 76 6 A 4.3 MB03
500 ET0500xxxyyy 38 4.2 125 117 135 99 70 91 6 A 5.9 MB03
750 ET0750xxxyyy 55 4.8 154 126 134 -- 125 103 6 B 8.9 MB04
1000 ET1000xxxyyy 63 4.6 154 136 134 -- 125 103 6 B 10.4 MB04
1500 ET1500xxxyyy 88 4.1 154 146 134 -- 125 103 6 B 11.4 MB04
2000 ET2000xxxyyy 105 3.9 184 160 180 -- 122 115 6 B 15.2 MB05
3000 ET3000xxxyyy 120 3.7 197 160 190 -- 135 125 8 B 21.2 MB05

ADD THE PRIMARY AND SECONDARY CODES BELOW TO COMPLETE
THE PART NOS. SHOWN ON THE TABLE ABOVE

PRI

xxx

220-240V

240

380-415-440V

415

SEC

yyy

12-24V

024

55-110V

110

240V

240

A

B

power losses inrush VA as a function of cos-phi short circuit regulation
VA W 0.9 0.8 0.7 0.6 0.5 0.4 voltage  % %
750 55 1050 1220 1450 1720 2020 2340 4.8 4.2
1000 63 1630 1850 2100 2380 2690 3030 4.6 4.1
1500 88 2700 2950 3250 3610 4040 4460 4.1 3.8
2000 105 3720 4100 4430 4700 5600 6000 3.9 3.6
2500 115 4200 4620 5050 5940 6650 7800 3.9 3.5
3000 120 5740 6580 7600 8470 9400 10730 3.7 3.3

DOWNLOAD THE PDF VERSION OF THE CATALOGUE

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL

Data shown on this page are for reference only and can be changed withouth further notice