home page

news

glossary of terms

data for the requests

stabilisers - guide

where we are

contact us

-------

PRODUCTS SUMMARY

single phase transformers 

control

ITAlia (50-3000VA)

EUR multitap (50-3000VA)

ET (50-3000VA)

TOR-toroidal (20VA-5kVA)

MC (4000-20000VA)

isolation and safety

TEcna (50-2000VA)

GT (50-2000VA) UL APPROVED

ALI (50-1000VA) LIGHTING 12V

TMIB for medical devices (0.3:2kVA)

TMIC (3000-25000VA)

TMI64 (3000-25000VA-medical)

specific use

ALX 200-500VA) ip55 class II

AL (50-1500VA) HALOGEN LAMPS

three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)
TTI-K NON LINEAR LOADS (15-300kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz
UP TO 9A

frequency converters 60-50Hz
FROM 20A TO 65A

GMM frequency converters 60-50Hz
FROM 3kVA TO 15kVA

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

SINGLE PHASE ISOLATION TRANSFORMERS TMIC range

 
POWER INPUT OUTPUT FREQUENCY STANDARDS
FROM 4000 TO 25000VA 230V 230V 50/60 Hz EN 61558-2-4
IEC 742
from 110 to 550V from 24 to 550V CEI 96-2
BS 3535
 Open type
 Protection IP00
 Isolation class H (At max 45°C)
 Separate copper windings cl. H
 Resing impregnated and tropicalised
 Earthed copper screen between primary and secondary
 Connections on terminal blocks up to 10kVA (or to 63A)
 connections on brass bolts up to 12,5kVA (or from 64A)
 Optional: mounted in metal enclosure RAL7032, IP23




power part no. losses short circ. regulation dimensions mm. DWG weight box
VA W voltage  % % A B C D E F kg. code
3150 TMIC03 130 3.5 3.0 240 230 320 200 125 12 A 34.0 SA02
4000 TMIC04 145 2.9 2.6 240 240 320 200 135 12 A 38.0 SA02
5000 TMIC05 180 2.7 2.6 240 250 320 200 145 12 A 44.0 SA02
6300 TMIC06 200 2.7 2.6 280 230 400 220 145 12 A 49.0 SA03
8000 TMIC08 210 2.7 2.6 280 240 400 220 155 12 A 60.0 SA03
10000 TMIC10 280 2.5 2.3 280 250 400 220 165 12 A 65.0 SA03
15000 TMIC15 400 2.5 2.2 320 260 450 260 185 12 B 92.0 SA04
20000 TMIC20 600 2.4 2.0 320 280 450 260 205 12 B 116.0 SA04
25000 TMIC25 700 2.1 2.0 320 280 450 260 205 12 B 131.0 SA04
ASK FOR CODES AND SPECIFICATION OF HIGHER RATINGS

A

B

PART NO SHOWN ABOVE REPRESENT THE STANDARD IN.230V-OUT.230V TYPE. IF DIFFERENT INPUT-OUTPUT VLTAGES ARE REQUIRED, THERE MUST BE SPECIFIED IN THE DESCRIPTION OF YOUR ORDER.

FOR SECONDARY VOLTAGE BELOW 50V A.C., TMIC TRANSFORMERS ARE MANUFACTURED ACCORDING THE EN61558-2-6 STANDARDS FOR SAFETY ISOLATION TRANSFORMERS

UL CERTIFIED VERSION AVAILABLE
RECOGNIZED COMPONENT (USA)
CONTACT US FOR YOUR ENQUIRIES

 

HOME PAGE  -  VERSIONE ITALIANA  -  CREDITS  -  COPYRIGHT - E-MAIL

Data shown on this page are for reference only and can be changed withouth further notice