three phase transformers

power

TTP (1-100kVA)

isolation and safety

TTI (1-40kVA)
TTI-K NON LINEAR LOADS (15-300kVA)

autotransfomers

SB 110/220V reversible

ATM (single ph. 0,1-5kVA)

KVA (three ph. 1-500kVA)

ATTP (three ph. 1-300kVA)

ATTP1 (three ph. +box 1-300kVA)

ATV (motor starting  7-220kW)

---------

metal enclosures

--------

voltage stabilisers

AVR voltage regulators

SEN single ph. electronic 

SED single ph. electronic

RA 1ph. servo motor 0,5-3kVA

Line conditioners for HI-FI 1.5-2.5k

RB single ph. electromechanical

R25 single ph. ±25% input

RTC three ph. electromechanical

RTC 220V three ph. NO NEUTRAL

RTI three ph.line conditioners

RTG three ph. electromechanical

uninterruptible power supplies

EB Unin.power supplies (UPS) to 2kVA

ECL sine wave ups to 3kVA

GET sine wave on-line ups to 10kVA

other products

frequency converters 60-50Hz
UP TO 9A

frequency converters 60-50Hz
FROM 20A TO 65A

GMM frequency converters 60-50Hz
FROM 3kVA TO 15kVA

Hospital earth leakage control

230V-110V ADAPTERS

Motor Guard (motor protection)

versione italiana

go to our UK Web site:
www.ideomat.co.uk

copyright 2001-2004 by:

web factory

THREE PHASE AUTOTRANSFORMERS ATTP range

 
 
POWER INPUT OUTPUT FREQUENCY STANDARDS
FROM 1KVA TO 500KVA 230/400V 230/400V 50/60 Hz EN 61558-2-13
CEI 14-4
BS 171
 Open type construction
 Protection IP00
 Isolation class F (Ta max 45°C)
 Copper windings cl. H
 Resin impregnated and tropicalised
 Connections on terminal blocks to 25kVA (or to 63A)
 Connections on brass bolts from 30kVA (or from 64A)
 Extra low losses grain oriented core from 40kVA
 Vector group: Yn0
 See the range in metal enclosure



power code losses (W) short circ. regulation dimensions mm. DWG weight box
KVA no load load volt. % % A B C D E F kg. code
1 ATTP179 12 50 3.0 3.0 180 120 150 145 70 6 A 7.3 SAM01
2 ATTP219 20 80 3.0 3.0 180 140 150 145 85 6 A 11.0 SAM01
3 ATTP249 28 100 3.0 2.5 240 145 185 175 90 6 A 17.0 SAM01
4 ATTP267 35 120 3.0 2.5 240 155 185 175 100 6 A 18.5 SAM01
5 ATTP287 40 150 3.0 2.5 240 170 185 175 115 6 A 22.0 SAM01
7.5 ATTP337 50 200 3.0 2.5 300 195 230 220 105 6 A 35.0 SAM02
10 ATTP387 55 230 3.0 2.5 300 205 230 220 115 6 A 39.0 SAM02
15 ATTP427 80 300 3.0 2.5 360 250 285 280 140 8 A 53.0 SAM03
20 ATTP467 90 320 3.0 2.5 360 260 285 280 150 8 A 62.0 SAM03
25 ATTP507 95 380 3.0 2.5 420 265 360 300 140 8 A 74.0 SAM04
30 ATTP547 105 420 3.0 2.5 420 295 360 300 170 8 A 94.0 SAM04
40 ATTP627 120 500 3.0 2.5 480 290 465 370 190 10 B 115.0 SAM05
50 ATTP707 150 600 3.0 2.5 480 290 465 370 190 10 B 125.0 SAM05
60 ATTP727 175 750 3.0 2.5 540 270 510 490 200 10 B 140.0 SAM07
70 ATTP747 180 800 3.0 2.5 540 270 510 490 200 10 B 152.0 SAM07
80 ATTP767 200 1000 3.0 2.5 540 270 510 490 200 10 B 160.0 SAM07
90 ATTP787 210 1200 3.0 2.5 540 370 510 490 200 10 B 165.0 SAM07
100 ATTP807 230 1400 3.0 2.5 540 370 510 490 200 10 B 178.0 SAM07
125 ATTP812 290 1600 3.0 2.5 690 340 660 600 210 10 B 235.0 SAM07
150 ATTP817 310 1850 3.0 2.5 690 340 660 300 200 10 B 258.0 SAM07
175 ATTP822 320 2100 3.0 2.5 690 340 660 300 200 10 B 280.0 SAM07
200 ATTP827 330 2350 3.0 2.5 690 340 660 300 200 10 B 300.0 SAM07
ASK FOR PART NOS. AND SPECIFICATION OF HIGHER RATINGS